Business
J-COS, Smart Jar-test techniques Coagulant-dosing Optimization System Jar-test Smart techniques Coagulant-dosing Optimization System
As a product that was selected and developed as a national research & development project through the MOU on joint development with Seonam/Jungnang Sewage Treatment Center in Seoul,
J-COS is a system that promptly analyzes water quality property in the rear end of bioreactor in sewerage/wastewater treatment facility and that of total phosphorus (T-P) processing facilities, and optimally controls coagulant-dosing in real time.
Major Project
Seoul, 2rd Plant in Jungnang Sewage Treatment Center
(460,000 m³/d, 2020.)
Seoul, Advanced treatment and facility modernization of Seonam Water Recycling Center
(360,000 m³/d, 2019)
Seoul, Advanced treatment and facility modernization of Jungnang Sewage Treatment Center
(250,000 m³/d, 2017)
Guri-si, 2rd Plant in public sewage treatment facility
(110,000 m³/d, 2020.)
Uijeongbu-si, Jangam Public Sewage Treatment Facilities
3rd Plant (73,000 m³/d, 2019)
Cheonan-si, Sewage Treatment Facility 3,4stage manufacturing purchase installation
(220,000 m³/d, 2020)
Gochang-gun, Daesan Sewage Treatment Center
(700 m³/d, 2020.)
Joint R&D with Seoul City
(Succeeded in national research & development project with conditional purchase options)
Seoul City
University of Seoul
Molit
Product Features
Pretreatment system using non-pressure gravity filtering method
- Prevents water quality measurement error caused by impurities, and failure of measuring equipment
- Automatic built-in water & chemical cleansing function
Accurately measures phosphorus concentration (P)
SMART Jar-test device (applying 5 min cycle PO4-P measurement equipment)
- Derives changes in efficiency of coagulant according to sewage flow property (phosphorus concentration, COD, alkalinity, etc.) through automatic jar-test
Promptly measures changes in water quality and properties, and optimally controls coagulant dosing
Overlap Process
- Promptly measures water quality and composes process to enable jar-test
Orders a 5-min unit optimal dosing
Feedback Control System
- Analyzes phosphorus concentration of process water before discharge -> Verifies coagulant dosing
Proactive response against emergencies
Complying with Legal Discharge Water Quality
Reduction of Coagulant Dosing by 20%
Increasing Operation Convenience
Technical Certification of J-COS
Excellent Product
Public Procurement Service
No. 2020228
No. 2020228
Excellent Performance
Ministry of SMEs and Startups
Seoul-20180551-1-11
Seoul-20180551-1-11
Green Technology Certification
Ministry of Environment
GT-17-00230
Prior purchasing for an excellent invention
K-Invention Promotion Association
No.2019-1306
No.2019-1306
Venture Start-up Innovative Product
Public Procurement Service
No.2020-03-0035
No.2020-03-0035
5 Registered patents & Design registration
Including “System of pretreating and controlling to find, in real-time, phosphorus concentration of sewage/wastewater and phosphorus concentration after jar-test and method there of”
No. 10-1253481, No. 10-1567539,
No. 10-1567541, No. 10-1728130,
No. 30-0781916
No. 10-1253481, No. 10-1567539,
No. 10-1567541, No. 10-1728130,
No. 30-0781916
Operation Case
Empirical Operation Case
- Seonam Water Recyacling Center in Seoul (About 9 months)
- Hwado 2nd Sewage Treatment Plant in Namyangju-si (About 6 months)
- Gwangju 2nd Sewage Treatment Plant (About 6 months)
Operation Case
- Real-time response in case of emergency (Repetition of rapid rise and decline of phosphorus concentration)
- Stably complies with discharge water quality
- Reduces about 20% of coagulant
Advanced operation & management technology
1Raw water inflow (Coagulation experiment tank, Pretreatment tank)
2Coagulant dosing
3Rapid(1min), Slow(3min) Stirring, Precipitation & Raw water pretreatment (filtration)
4Mesurement of Phosphorus Concentration in Raw Water
5Order of Coagulant dosing & moving Coagulation effluent to Pretreatment tank
6Pretreatment of Coagulation effluent(filtration)
7Measurement of Phosphorus Concentration in Coagulation effluent
8Calculating of Coagulant Efficiency
9Order of Coagulant dosing